Configure the distribution of
power flow through each component in the system.
Infeed Power Distribution
Continuous Power
Divided equally
In a system with two drives,
Drive 1 and Drive 2 each share 50% of the system continuous power
requirement
Proportional to continuous
power rating
If Drive 1 has twice the
continuous rating of Drive 2, then Drive 1 and Drive 2 bear 66% and
33% respectively of the system continuous power
requirement
Peak Power
Same as continuous
power
System peak power
requirement
Sets the application system
peak power requirement as the peak power requirement for each
drive/infeed
Bleeder Power
Distribution
Continuous Power
Divided equally
In a system with two bleeders,
Bleeder 1 and Bleeder 2 each share 50% of the system continuous
bleeder power requirement
Proportional to continuous
power rating
If Bleeder 1 has twice the
continuous rating of Bleeder 2, then Bleeder 1 and Bleeder 2 bear
66% and 33% respectively of the system continuous bleeder power
requirement
Proportional to resistor
current
Based on resistor current
(Vdc/R)
Put another way, inversely
proportional to resistor ohms
Peak Power
Same as continuous
power
System peak power
requirement
Sets the application system
peak power requirement as the peak power requirement for each
drive/infeed